Technical description
Cells management
- Management of 6 lithium cells in series, compatible with all cell technologies (NMC, LiFe, LiPo…)
- Management of 2 NTC temperature sensors
- Measurements accuracy:
- Cell voltages: +/- 5 mV
- Temperatures: +/- 1°C
Protections
- Over-current software protection:
- several configurable levels during charge and discharge phases
- Overdischarge, overcharge, overtemperature protection
- Short circuit hardware protection (electronic fuse):
- Above 56 A for more than 100 µs
Balancing
- Passive balancing with a 100 mA bypass current
Power box
- Integrated power box with MOSFET technology:
- 45 A continuous current in discharge
- 55 A maximum peak current in discharge
- 20 A continuous current in charge
- Bidirectional current measurement
- Precharge circuit included on the BMS
Smart functions
- SOC and SOH estimatio
- Management of a push button or switch to wake up the battery
- Automatic detection of the charger connection with wake up of the BMS
- Advanced self-diagnostic of the board
- Communication by CAN bus 2.0B
- Advanced supervision software
- Black box integrated with defaults history storage and life counters
- Possibility to connect up to 10 packs in parallel
Power supply/consumption
- Supply of the BMS directly on the battery pack
- Low consumption in sleep mode: < 60 μA
Mechanical format
- 130 mm x 61 mm x 11 mm
6S BMS PowerSafe®Alexy Garas2021-02-15T12:20:52+01:00